Dataset

cyclic voltammetry (CV)

dataset for cyclic voltammetry (CV)\n\n

Chemical Info

molecular Image
InChI InChI=1S/2C14H12N2.BF4.Cu/c2*1-9-3-5-11-7-8-12-6-4-10(2)16-14(12)13(11)15-9;2-1(3,4)5;/h2*3-8H,1-2H3;;/q;;-1;+1
SMILES F[B-](F)(F)F.Cc1ccc2c(n1)c1nc(C)ccc1cc2.Cc1ccc2c(n1)c1nc(C)ccc1cc2.[Cu+]
InChI Key PHXDKLQHLVWUNE-UHFFFAOYSA-N
Exact Mass 566.868 g/mol

Data and Resources

Metadata Information

Field Value
DOI 10.14272/PHXDKLQHLVWUNE-UHFFFAOYSA-N/CHMO0000025.1
License URL
Source https://www.chemotion-repository.net/inchikey/PHXDKLQHLVWUNE-UHFFFAOYSA-N/CHMO0000025.1
Version
Author Niklas Oppel
Maintainer Chemotion Repository
Language english
MetadataCreated 2024-09-08T03:51:06.186185
MetadataModified 2024-09-23T09:25:13.083705
MetadataPublished 2024-06-05
Field Value
Measurement Technique cyclic voltammetry
Measurement Variables
Operation mode : without motion

Atmosphere : nitrogen

Temperature : 0 °C K

Separation : none

Conditions : daylight

Internal reference : none

No of cycles : 3

Scan rate [V/s] : 0.0999998

Step size [V] : 0.005

Voltage limit 1 [V] : 1.00000E+000

Voltage limit 2 [V] : 0.00000E+000

Plotting convention : IUPAC

Date : 25.1.2024

Time : 11:20:21

operator : NO

Software : Framework

Software version : 7.10.1

Used electrodes : traditional

Polishing material : diamond

Particle size : 0.00025 mm

Working electrode (WE) : platinum

WE-area [mm²] : 19.63

Counter electrode (CE) : platinum

Reference electrode (RE) : Ag1

Brand : Gamry

Serial No : IFC1010-30012

Instrument : Potentiostat

label : NO5-16

id : 113077

Amount : 5.66 mg

Volume : 0 l

Solvent : MeCN

Volume of solvent : 10 ml

Concentration of analyte : 1 mmol/L

Supporting electrolyte : TBAPF6

Amount supporting electrolyte : 0 g

Concentration supporting electrolyte : 0.1 mol/L

Purge gas : nitrogen

Purge time : 10 m

Data-Source Molecule ID Data-Source
139130958 PubChem
The data in this table is sourced from UniChem at EBI.